2088 Compact Pressure Transmitter TY812 Series

  • Ranges from 0–1 kPa up to 0–100 MPa; gauge, absolute and vacuum (negative) pressure
  • Accuracy classes ±0.1%FS, ±0.25%FS, ±0.5%FS
  • 2-wire 4–20 mA; RS485, 4–20 mA + HART, 0–5 VDC, 0–10 VDC selectable
  • 200% of span overload; vibration resistance 20 g, 20–5000 Hz; shock 100 g, 11 ms
  • High-temperature variant to -40–200 °C; flush-diaphragm flange and sanitary clamp versions
  • Intrinsically safe and flameproof options; LCD or LED display optional
Request a QuoteWhatsApp

Tell us your medium, range and process connection — we reply within 24 hours.

Factory-direct from WELK Meters

  • Check Mark Small MOQ Welcome
  • Check Mark OEM / ODM Support
  • Check Mark Reply Within 24 Hours
SKU: TY812 Category:

Overview

The TY812 is a 2088-type compact pressure transmitter that measures gauge pressure, absolute pressure and vacuum (negative pressure) of liquids, gases and steam, with measuring ranges from 0–1 kPa up to 0–100 MPa and a 2-wire 4–20 mA output (RS485, 4–20 mA + HART, 0–5 VDC and 0–10 VDC selectable). Accuracy classes of ±0.1%FS, ±0.25%FS and ±0.5%FS are available.

The transmitter adopts diffused-silicon sensing technology together with laser trimming, temperature compensation and analog signal conditioning. When the measured medium acts on the sensing diaphragm, its deformation is converted into an electrical signal, which is amplified, filtered and digitized before being output as a reliable standard signal. The result is high accuracy, high reliability, fast response and excellent long-term stability.

With a simple structure, easy installation and convenient maintenance, the TY812 is well suited to long-distance signal transmission. It is widely used in petroleum, chemical, metallurgy, pharmaceutical, electric power and light industries, and is offered in conventional, standard, high-temperature, flush-diaphragm flange and sanitary clamp variants.

Features

  • Intelligent 2-wire 4–20 mA operation; improved anti-interference capability and lossless long-distance signal transmission
  • Dedicated custom ASSIC circuit with higher integration and better reliability
  • Full digital calibration and intelligent push-button configuration — no potentiometers, low temperature drift
  • Reinforced EMC anti-interference design; rugged hardware suitable for harsh electromagnetic industrial environments
  • Built-in backup function: factory settings can be restored on site after mis-operation
  • Imported diffused-silicon sensor chip with high measurement accuracy and stability
  • Optional display head; on-site indication shows the pressure at a glance

Specifications

Parameter Value
Power supply 12–36 VDC (non-standard supply customizable); standard type: 9–36 VDC
Output signal 4–20 mA, RS485, 4–20 mA + HART, 0–5 VDC, 0–10 VDC (selectable)
Measuring range 0–1 kPa minimum up to 0–100 MPa; vacuum/compound ranges from -100 kPa (see range selection table)
Accuracy class ±0.25%FS, ±0.5%FS, ±0.1%FS
Pressure types Gauge, absolute, negative (vacuum)
Overload limit 200% of span
Compensated temperature range -10–70 °C
Temperature effect ±0.01%FS/°C (within compensated range)
Medium temperature -40–80 °C (conventional / standard type); -40–200 °C (high-temperature, flange, and sanitary types; ultra-high-temperature customizable)
Ambient temperature -20–70 °C
Measured media Liquids or gases compatible with the wetted materials (compatible with 316L stainless steel)
Process connection M20×1.5, G1/2, G1/4, 1/2NPT, M27×2 (internal/external thread, customizable); flange type: DN25 flange and above; sanitary clamp type: Ø50.5, Ø64 clamps (others customizable)
Housing Cast aluminum; stainless steel housing optional
Display No display / LCD / LED digital tube (optional)
Vibration resistance 20 g, 20–5000 Hz
Shock resistance 100 g, 11 ms

Product variants

Variant Power supply Medium temperature Process connection Notes
TY812 Conventional type 12–36 VDC -40–80 °C M20×1.5, G1/2, 1/2NPT internal/external thread, customizable Digital tube or LCD display (optional); gauge/absolute/negative; 200% overload
TY812 Standard type 9–36 VDC -40–80 °C M20×1.5, G1/2, 1/2NPT, M27×2, customizable No display; gauge/absolute/negative; 200% overload
TY812 High-temperature type 12–36 VDC -40–200 °C (ultra-high-temperature customizable) M20×1.5, G1/2, 1/2NPT internal/external thread, customizable Digital tube or LCD display (optional)
TY812 Flush-diaphragm flange type 12–36 VDC -40–200 °C DN25 flange and above Digital tube or LCD display (optional)
TY812 Sanitary clamp type 12–36 VDC -40–200 °C Ø50.5, Ø64 clamp, others customizable Digital tube or LCD display (optional)

Ordering Code

Item Code Description
TY812 Intelligent pressure transmitter
Range (fill in) Fill in the required measuring range; per customer requirement, minimum -100 kPa, maximum 100 MPa
Output signal A / B / C / D / E / F A = 4–20 mA; B = 0–5 V; C = 0–10 V; D = RS485; E = 4–20 mA + HART; F = custom
Threaded connection 1 / 2 / 3 / 4 1 = M20×1.5; 2 = G1/2; 3 = G1/4; 4 = other
Display head A / B / C A = no display; B = LCD display; C = LED digital tube display
Explosion-proof class 1 / 2 / 3 1 = ordinary (non-Ex); 2 = intrinsically safe; 3 = flameproof
Accuracy class F / G / H F = 0.5%; G = 0.2%; H = 0.1%

Ordering example: TY812 0-10kPa A 1 A 1 F

Range selection table

Code Range Code Range
W1 0–1 kPa W2 0–2 kPa
W3 0–3 kPa W4 0–4 kPa
W5 0–6 kPa W6 0–10 kPa
W7 0–20 kPa W9 0–25 kPa
W10 0–40 kPa W11 0–60 kPa
W12 0–100 kPa W13 0–0.16 MPa
W14 0–0.25 MPa W15 0–0.4 MPa
W16 0–0.6 MPa W17 0–1.0 MPa
W18 0–1.6 MPa W19 0–2.5 MPa
W20 0–4 MPa W21 0–6 MPa
W22 0–10 MPa W23 0–16 MPa
W24 0–25 MPa W25 0–40 MPa
W26 0–60 MPa W27 0–100 MPa

Vacuum and compound (negative-pressure) ranges from -100 kPa, as well as other custom ranges, are available — contact us with your required range.

Applications

  • Petroleum and petrochemical
  • Chemical industry
  • Metallurgy
  • Pharmaceutical
  • Electric power
  • Light industry
  • Measurement and control of pressure, absolute pressure and vacuum of liquids, gases and steam
  • Hydraulic and pneumatic systems

FAQ

What pressure types can the TY812 measure?

The TY812 measures gauge pressure, absolute pressure and negative (vacuum) pressure of liquids, gases and steam, with standard ranges from 0–1 kPa up to 0–100 MPa and vacuum/compound ranges from -100 kPa.

Is there a version for high-temperature or sanitary media?

Yes. The high-temperature, flush-diaphragm flange and sanitary clamp variants handle medium temperatures of -40–200 °C (ultra-high-temperature customizable). The sanitary type uses Ø50.5 or Ø64 clamps; the flange type uses DN25 flanges and above.

How do I order the right TY812 configuration?

Contact us with your medium, range and process connection; we respond within 24 hours. A typical ordering code looks like TY812 0-10kPa A 1 A 1 F (range, output, thread, display, Ex class, accuracy).

Request a Quote for This Product

Get a Quote