2088 Compact Pressure Transmitter TY812 Series
- Ranges from 0–1 kPa up to 0–100 MPa; gauge, absolute and vacuum (negative) pressure
- Accuracy classes ±0.1%FS, ±0.25%FS, ±0.5%FS
- 2-wire 4–20 mA; RS485, 4–20 mA + HART, 0–5 VDC, 0–10 VDC selectable
- 200% of span overload; vibration resistance 20 g, 20–5000 Hz; shock 100 g, 11 ms
- High-temperature variant to -40–200 °C; flush-diaphragm flange and sanitary clamp versions
- Intrinsically safe and flameproof options; LCD or LED display optional
Tell us your medium, range and process connection — we reply within 24 hours.
Factory-direct from WELK Meters
- Small MOQ Welcome
- OEM / ODM Support
- Reply Within 24 Hours
Overview
The TY812 is a 2088-type compact pressure transmitter that measures gauge pressure, absolute pressure and vacuum (negative pressure) of liquids, gases and steam, with measuring ranges from 0–1 kPa up to 0–100 MPa and a 2-wire 4–20 mA output (RS485, 4–20 mA + HART, 0–5 VDC and 0–10 VDC selectable). Accuracy classes of ±0.1%FS, ±0.25%FS and ±0.5%FS are available.
The transmitter adopts diffused-silicon sensing technology together with laser trimming, temperature compensation and analog signal conditioning. When the measured medium acts on the sensing diaphragm, its deformation is converted into an electrical signal, which is amplified, filtered and digitized before being output as a reliable standard signal. The result is high accuracy, high reliability, fast response and excellent long-term stability.
With a simple structure, easy installation and convenient maintenance, the TY812 is well suited to long-distance signal transmission. It is widely used in petroleum, chemical, metallurgy, pharmaceutical, electric power and light industries, and is offered in conventional, standard, high-temperature, flush-diaphragm flange and sanitary clamp variants.
Features
- Intelligent 2-wire 4–20 mA operation; improved anti-interference capability and lossless long-distance signal transmission
- Dedicated custom ASSIC circuit with higher integration and better reliability
- Full digital calibration and intelligent push-button configuration — no potentiometers, low temperature drift
- Reinforced EMC anti-interference design; rugged hardware suitable for harsh electromagnetic industrial environments
- Built-in backup function: factory settings can be restored on site after mis-operation
- Imported diffused-silicon sensor chip with high measurement accuracy and stability
- Optional display head; on-site indication shows the pressure at a glance
Specifications
| Parameter | Value |
|---|---|
| Power supply | 12–36 VDC (non-standard supply customizable); standard type: 9–36 VDC |
| Output signal | 4–20 mA, RS485, 4–20 mA + HART, 0–5 VDC, 0–10 VDC (selectable) |
| Measuring range | 0–1 kPa minimum up to 0–100 MPa; vacuum/compound ranges from -100 kPa (see range selection table) |
| Accuracy class | ±0.25%FS, ±0.5%FS, ±0.1%FS |
| Pressure types | Gauge, absolute, negative (vacuum) |
| Overload limit | 200% of span |
| Compensated temperature range | -10–70 °C |
| Temperature effect | ±0.01%FS/°C (within compensated range) |
| Medium temperature | -40–80 °C (conventional / standard type); -40–200 °C (high-temperature, flange, and sanitary types; ultra-high-temperature customizable) |
| Ambient temperature | -20–70 °C |
| Measured media | Liquids or gases compatible with the wetted materials (compatible with 316L stainless steel) |
| Process connection | M20×1.5, G1/2, G1/4, 1/2NPT, M27×2 (internal/external thread, customizable); flange type: DN25 flange and above; sanitary clamp type: Ø50.5, Ø64 clamps (others customizable) |
| Housing | Cast aluminum; stainless steel housing optional |
| Display | No display / LCD / LED digital tube (optional) |
| Vibration resistance | 20 g, 20–5000 Hz |
| Shock resistance | 100 g, 11 ms |
Product variants
| Variant | Power supply | Medium temperature | Process connection | Notes |
|---|---|---|---|---|
| TY812 Conventional type | 12–36 VDC | -40–80 °C | M20×1.5, G1/2, 1/2NPT internal/external thread, customizable | Digital tube or LCD display (optional); gauge/absolute/negative; 200% overload |
| TY812 Standard type | 9–36 VDC | -40–80 °C | M20×1.5, G1/2, 1/2NPT, M27×2, customizable | No display; gauge/absolute/negative; 200% overload |
| TY812 High-temperature type | 12–36 VDC | -40–200 °C (ultra-high-temperature customizable) | M20×1.5, G1/2, 1/2NPT internal/external thread, customizable | Digital tube or LCD display (optional) |
| TY812 Flush-diaphragm flange type | 12–36 VDC | -40–200 °C | DN25 flange and above | Digital tube or LCD display (optional) |
| TY812 Sanitary clamp type | 12–36 VDC | -40–200 °C | Ø50.5, Ø64 clamp, others customizable | Digital tube or LCD display (optional) |
Ordering Code
| Item | Code | Description |
|---|---|---|
| TY812 | — | Intelligent pressure transmitter |
| Range | (fill in) | Fill in the required measuring range; per customer requirement, minimum -100 kPa, maximum 100 MPa |
| Output signal | A / B / C / D / E / F | A = 4–20 mA; B = 0–5 V; C = 0–10 V; D = RS485; E = 4–20 mA + HART; F = custom |
| Threaded connection | 1 / 2 / 3 / 4 | 1 = M20×1.5; 2 = G1/2; 3 = G1/4; 4 = other |
| Display head | A / B / C | A = no display; B = LCD display; C = LED digital tube display |
| Explosion-proof class | 1 / 2 / 3 | 1 = ordinary (non-Ex); 2 = intrinsically safe; 3 = flameproof |
| Accuracy class | F / G / H | F = 0.5%; G = 0.2%; H = 0.1% |
Ordering example: TY812 0-10kPa A 1 A 1 F
Range selection table
| Code | Range | Code | Range |
|---|---|---|---|
| W1 | 0–1 kPa | W2 | 0–2 kPa |
| W3 | 0–3 kPa | W4 | 0–4 kPa |
| W5 | 0–6 kPa | W6 | 0–10 kPa |
| W7 | 0–20 kPa | W9 | 0–25 kPa |
| W10 | 0–40 kPa | W11 | 0–60 kPa |
| W12 | 0–100 kPa | W13 | 0–0.16 MPa |
| W14 | 0–0.25 MPa | W15 | 0–0.4 MPa |
| W16 | 0–0.6 MPa | W17 | 0–1.0 MPa |
| W18 | 0–1.6 MPa | W19 | 0–2.5 MPa |
| W20 | 0–4 MPa | W21 | 0–6 MPa |
| W22 | 0–10 MPa | W23 | 0–16 MPa |
| W24 | 0–25 MPa | W25 | 0–40 MPa |
| W26 | 0–60 MPa | W27 | 0–100 MPa |
Vacuum and compound (negative-pressure) ranges from -100 kPa, as well as other custom ranges, are available — contact us with your required range.
Applications
- Petroleum and petrochemical
- Chemical industry
- Metallurgy
- Pharmaceutical
- Electric power
- Light industry
- Measurement and control of pressure, absolute pressure and vacuum of liquids, gases and steam
- Hydraulic and pneumatic systems
FAQ
What pressure types can the TY812 measure?
The TY812 measures gauge pressure, absolute pressure and negative (vacuum) pressure of liquids, gases and steam, with standard ranges from 0–1 kPa up to 0–100 MPa and vacuum/compound ranges from -100 kPa.
Is there a version for high-temperature or sanitary media?
Yes. The high-temperature, flush-diaphragm flange and sanitary clamp variants handle medium temperatures of -40–200 °C (ultra-high-temperature customizable). The sanitary type uses Ø50.5 or Ø64 clamps; the flange type uses DN25 flanges and above.
How do I order the right TY812 configuration?
Contact us with your medium, range and process connection; we respond within 24 hours. A typical ordering code looks like TY812 0-10kPa A 1 A 1 F (range, output, thread, display, Ex class, accuracy).