- Thermocouple types S, K and E; special and armored (mineral-insulated) constructions
- Type S long-term service up to 1300 °C
- Type K long-term 700–1200 °C by wire diameter; type E 350–750 °C
- Wire diameters 0.3–3.2 mm per max-temperature table
- Sheath materials GH3030, GH3030+310S, 1Cr18Ni9Ti, 304, 316
- Armored sheath GH3030 long-term 1100 °C; 1Cr18Ni9Ti/304/316 long-term 800 °C
-

- 4–20 mA output, DC24V supply
- Temperature accuracy ±0.5 °C
- Response time ≤10 s
- Ambient -20–80 °C, ≤95% RH
- Thread or flange mounting
-

- PT100 platinum RTD sensing element, measuring range -200–1300 °C
- Output 4–20 mA, 0–5 VDC or 0–10 VDC; RS485 / RS232 / HART optional
- Accuracy 0.2% / 0.5%; long-term stability better than 0.2%/year
- Explosion-proof rating Ex d II CT6 (as printed), IP65 protection
- 24 VDC supply, power consumption ≤1 W, load resistance ≤500 Ω
- Threads M20×1.5, M27×2, G1/2, G1/4; probe stem 8 / 10 / 12 mm, fully customizable
-

- Dial sizes Φ60, Φ100 and Φ150 mm
- Measuring ranges from -80–40 °C up to 0–500 °C (per model table)
- Accuracy class 1.5
- Radial, axial and electric-contact (switching/alarm) forms
- Stem Φ6 / Φ10; threads M16×1.5, M20×1.5, M27×2, NPT
-

- Measuring range -80–500 °C
- Accuracy ±1% F·S; long-term stability ±0.5% F·S/year
- Radial (WST-411), axial (WST-401) and WST-481 forms
- Stem Φ12; insertion length 100–2000 mm, customizable
- Process connection 1/2″, 3/4″ or M27×2 (customizable)
- For gases and liquids (specify corrosive media when ordering)
Temperature Measurement Guide
From local dial thermometers to smart 4–20 mA transmitters, temperature instrumentation spans -200 °C to 1300 °C. WELK Meters manufactures WSS bimetal thermometers, WST digital thermometers, industrial RTDs and thermocouples (types S, K, E, including armored construction), and the TY862 intelligent PT100 temperature transmitter with HART/RS485 options.
How to choose
- Local indication only — WSS bimetal (Φ60/Φ100/Φ150 dials) or WST digital thermometers; electric-contact versions add switching at a set temperature.
- Signal to PLC/DCS — TY862 transmitter with PT100 element, 4–20 mA / HART / RS485 output and 0.2% accuracy.
- High temperatures — thermocouples: type K up to 1200 °C, type S up to 1300 °C; armored sheaths for mechanical protection.
- Process connection — threads M20×1.5/M27×2/G1/2, sanitary clamps or DN25–DN50 flanges; insertion length customizable.
Send us your temperature range, medium and insertion depth and we will return a full ordering code within 24 hours.