- Ranges from 0–1 kPa up to 0–100 MPa; gauge, absolute and vacuum (negative) pressure
- Accuracy classes ±0.1%FS, ±0.25%FS, ±0.5%FS
- 2-wire 4–20 mA; RS485, 4–20 mA + HART, 0–5 VDC, 0–10 VDC selectable
- 200% of span overload; vibration resistance 20 g, 20–5000 Hz; shock 100 g, 11 ms
- High-temperature variant to -40–200 °C; flush-diaphragm flange and sanitary clamp versions
- Intrinsically safe and flameproof options; LCD or LED display optional
-

- Measuring range -0.1~60MPa; accuracy ≤±0.25%FS
- Long-term stability <0.2%/year; supply 12-32VDC; IP65
- Outputs 4-20mA (2-wire), 0-5V / 1-5V / 0-10V
- Working temperature -30~80℃; medium temperature -40℃~120℃
- Six sensor variants: ceramic, diffused-silicon, digital display (131S), high-temperature (131G), sanitary (131MC), flush-diaphragm (131PM)
- Threads M20x1.5, M12x1.5, M14x1.5, G1/4, G1/2, 1/2NPT, 1/4NPT
-

- Diaphragm seal isolates the sensor from corrosive, viscous or crystallizing media
- Two process interfaces: flange-mounted or threaded diaphragm seal
- Based on our explosion-proof transmitter family: -0.1~60MPa, ≤±0.25%FS
- Output 4~20mADC; supply 12-32VDC; IP65
- Long-term stability <0.2%/year
-

- Intrinsically safe design for hazardous areas
- Measuring range -0.1~60MPa; accuracy ≤±0.25%FS (0.5 and 0.25 accuracy-class variants)
- Output 4~20mADC; supply 12-32VDC
- Industrial explosion-proof housing with digital pressure display
- Long-term stability <0.2%/year; IP65; working temperature -30~70℃
-

- Reference accuracy up to ±0.05%; spans from 0.1 kPa up to 40 MPa
- 2-wire 4–20 mA output; HART, RS485, 0–5 V and 0–10 V selectable
- IP66 / IP67 protection; Ex ia IIC T6 Gb intrinsically safe or Ex d IIC T6 Gb flameproof options
- MEMS monocrystalline silicon sensor with dual-diaphragm overload protection
- 8 variants: gauge, absolute, differential, flange, capillary remote-seal and level types
- Capillary remote-seal versions handle media up to 420 °C
-

- Reference accuracy 0.075% (±0.075% and ±0.2% options); stability ±0.01%/year
- 100:1 turndown; output 4-20mA DC with HART
- Differential (DP), gauge (GP) and absolute (AP) pressure inputs
- Supply 11.9~45VDC; HART load 250~1500Ω; start-up time 5s
- Isolating diaphragms: 316LSS, Hastelloy C-276, tantalum, Monel
- Approvals listed: CSA, FM, ATEX, GOST; single and double remote-seal variants
Pressure Transmitter Buying Guide
A pressure transmitter converts process pressure into a standard electrical signal — typically 2-wire 4–20 mA, optionally with HART or RS485 — so PLCs, DCS and recorders can monitor and control a process. WELK Meters manufactures monocrystalline silicon and diffused-silicon transmitters for gauge, absolute, differential and remote-seal applications, with reference accuracy up to ±0.05% and ranges from 100 Pa to 100 MPa.
How to choose a pressure transmitter
- Measurement type — gauge, absolute, vacuum, or differential pressure. Differential models (such as the TY813DP) also derive flow and tank level.
- Range — select a nominal range so your normal operating point sits in the middle; consider turndown when conditions vary.
- Accuracy — ±0.05%, ±0.1% or ±0.25% for monocrystalline silicon; ±0.25% / ±0.5% classes for compact diffused-silicon types like the TY812.
- Process connection & wetted parts — M20×1.5, G1/2, NPT threads or DN25–DN100 flanges; 316L, Hastelloy C, tantalum or PTFE-coated diaphragms for corrosive media.
- Temperature — direct-mount types serve -40–120 °C; capillary remote-seal versions handle media up to 420 °C.
- Hazardous areas — choose intrinsically safe Ex ia IIC T6 Gb or flameproof Ex d IIC T6 Gb versions with IP66/IP67 housings.
Monocrystalline silicon vs diffused silicon
Monocrystalline (single-crystal) silicon sensors offer superior long-term stability and accuracy and excel in differential-pressure flow and level duty. Diffused-silicon designs such as the 2088-style TY812 are compact and economical for general gauge-pressure monitoring. Not sure which fits your process? Send us your medium, range and process conditions — our engineers reply within 24 hours with a complete model selection and ordering code.