Explosion-Proof Pressure Transmitter

  • Intrinsically safe design for hazardous areas
  • Measuring range -0.1~60MPa; accuracy ≤±0.25%FS (0.5 and 0.25 accuracy-class variants)
  • Output 4~20mADC; supply 12-32VDC
  • Industrial explosion-proof housing with digital pressure display
  • Long-term stability <0.2%/year; IP65; working temperature -30~70℃
Request a QuoteWhatsApp

Tell us your medium, range and process connection — we reply within 24 hours.

Factory-direct from WELK Meters

  • Check Mark Small MOQ Welcome
  • Check Mark OEM / ODM Support
  • Check Mark Reply Within 24 Hours

Overview

The WELK Meters explosion-proof pressure transmitter is an intrinsically safe transmitter for hazardous-area pressure measurement, covering ranges of -0.1~60MPa with accuracy ≤±0.25%FS and a 4~20mADC output. It combines an industrial explosion-proof housing with a diffused-silicon sensing core and an on-board digital pressure display.

The transmitter runs on a 12-32VDC supply, carries an IP65 protection rating, operates at working temperatures of -30~70℃ and offers long-term stability of <0.2%/year. It is offered in 0.5-class and 0.25-class accuracy variants.

The same transmitter family is also available with flange-diaphragm and threaded diaphragm-seal process interfaces — see our diaphragm-seal pressure transmitter page, or contact us with your hazardous-area classification and process details for a configuration recommendation.

Features

  • Intrinsically safe explosion protection for hazardous areas
  • Industrial explosion-proof housing
  • Diffused-silicon sensing core
  • On-board digital pressure display
  • 0.5-class and 0.25-class accuracy variants
  • Long-term stability <0.2%/year

Specifications

Parameter Value
Measuring range -0.1~60MPa
Accuracy ≤±0.25%FS (0.5-class and 0.25-class variants)
Long-term stability <0.2%/year
Output signal 4~20mADC
Power supply 12-32VDC
Protection rating IP65
Working temperature -30~70℃
Explosion protection Intrinsically safe
Display Digital pressure display

Applications

  • Pressure measurement in hazardous (explosive-atmosphere) areas
  • Petrochemical and chemical plants
  • Industrial processes requiring local digital indication plus a 4~20mADC loop signal

FAQ

What type of explosion protection does this transmitter use?

It is an intrinsically safe design housed in an industrial explosion-proof enclosure. Contact us with your hazardous-area classification and we will confirm the suitable version.

What accuracy options are available?

The family is offered in 0.5-class and 0.25-class accuracy variants, with overall accuracy ≤±0.25%FS and long-term stability <0.2%/year.

How do I request a quote?

Contact us with your medium, range and process connection; we respond within 24 hours.

Request a Quote for This Product

Get a Quote