WK-300 Ultrasonic Flow Meter: Inline, Clamp-On, Open-Channel

  • Transit-time ultrasonic flowmeter family: inline (pipe-section), clamp-on and open-channel versions
  • Accuracy better than 1%, repeatability better than 0.2%; 500ms measuring period (128 samples)
  • Inline sizes: flanged DN15-1000 (rated 2.5/1.6/1.0/0.6 MPa by size), union (sanitary) DN25-100
  • Outputs: isolated RS485, OCT pulse, relay, 4-20mA; protocols MODBUS, M-BUS, FUJ extended
  • Inputs: 3× 4-20mA (pressure/level/temperature) + 2× 3-wire PT100; data logging 512 days / 128 months / 10 years
  • Supply isolated DC8~36V or AC85~264V; IP65/IP68
Request a QuoteWhatsApp

Tell us your medium, range and process connection — we reply within 24 hours.

Factory-direct from WELK Meters

  • Check Mark Small MOQ Welcome
  • Check Mark OEM / ODM Support
  • Check Mark Reply Within 24 Hours
SKU: WK-300 Category:

Overview

The WK-300 ultrasonic flow meter measures liquid flow with accuracy better than 1% and repeatability better than 0.2%, resolving velocities up to 64m/s at 0.001m/s resolution. It samples 128 times per 500ms measuring period (2 measurements per second) and outputs isolated RS485, OCT pulse, relay and 4-20mA signals over MODBUS, M-BUS and FUJ extended protocols.

The family is offered in three forms covered by this product page: an inline (pipe-section) version with flanged connections from DN15-1000 (rated 2.5/1.6/1.0/0.6 MPa depending on size) or union/sanitary connections from DN25-100; a clamp-on version pairing a wall-mounted converter with externally clamped transducers — no pipe cutting required; and an open-channel version that combines the wall-mount converter with flume/weir measurement for channels and outfalls.

The converter runs from an isolated DC8~36V or AC85~264V supply and features a 2×10 Chinese-character backlit LCD. Beyond flow, it accepts 3× 4-20mA analog inputs (0.1%, for pressure/level/temperature signals) and 2× 3-wire PT100 inputs. Built-in data logging stores 512 daily, 128 monthly and 10 yearly positive/negative/net totals plus the last 30 power-off events. Protection class is IP65/IP68.

Features

  • Accuracy better than 1%; repeatability better than 0.2%
  • Three forms in one family: inline pipe-section, clamp-on, open-channel
  • Velocity range up to 64m/s with 0.001m/s resolution
  • OCT pulse output programmable 6~1000ms (default 200ms)
  • 3× 4-20mA inputs + 2× 3-wire PT100 inputs for heat/energy-style measurements
  • Logging: 512 days / 128 months / 10 years of +/-/net totals; last 30 power-off events recorded
  • Isolated DC8~36V or AC85~264V supply; IP65/IP68 enclosures

Specifications

Item Value
Model WK-300
Accuracy Better than 1%
Repeatability Better than 0.2%
Measuring period 500ms (2 per second, 128 samples per period)
Velocity Max 64m/s, resolution 0.001m/s
Power supply Isolated DC8~36V or AC85~264V
Display 2×10 Chinese-character backlit LCD
Analog inputs 3× 4-20mA (0.1%; pressure/level/temperature) + 2× 3-wire PT100
Outputs Isolated RS485, isolated OCT pulse (6~1000ms programmable, default 200ms), relay, 4-20mA
Protocols MODBUS, M-BUS, FUJ extended
Data logging 512 days / 128 months / 10 years +/-/net totals; last 30 power-off events
Protection class IP65/IP68

Versions and connections

Version Connection / arrangement
Inline (pipe-section), flanged DN15-1000; rated 2.5 / 1.6 / 1.0 / 0.6 MPa per size table
Inline (pipe-section), union (sanitary) DN25-100
Clamp-on Wall-mounted converter + clamp-on transducers, no pipe cutting
Open-channel Wall-mounted converter + flume/weir measurement set

Applications

  • Clean water and process liquid metering in pipes DN15-1000
  • Retrofit flow measurement without shutting down the line (clamp-on)
  • Sanitary lines using union connections (DN25-100)
  • Open channels, irrigation and outfall measurement (flume/weir version)
  • Energy/heat-balance measurement using the PT100 and 4-20mA inputs

FAQ

Inline, clamp-on or open-channel — which version do I need?

Choose the inline pipe-section version for the highest confidence on new installations (flanged DN15-1000 or union DN25-100), the clamp-on version when you cannot cut the pipe, and the open-channel version for flumes, weirs and channels. All share the same WK-300 converter electronics.

Can the WK-300 log historical flow data?

Yes. It stores 512 daily, 128 monthly and 10 yearly records of positive, negative and net totals, and records the last 30 power-off events for audit purposes.

How do I get a quote?

Contact us with your medium, pipe size or channel dimensions, and flow range; we respond within 24 hours with a version recommendation and quotation.

Request a Quote for This Product

Get a Quote